Canature 06 Model
General Information
Inlet / Outlet Fittings: 1/2", 3/4", 1", NPT & BSP
Cycles: Up to 9
Valve Material: PPO
Regeneration: Downflow
Flow Rates
Service @ 15 psi drop (includes bypass and meter): 15.4 gpm / 3.5 m³/h
Backwash @ 25 psi drop (includes bypass): 15.4 gpm / 3.5 m³/h
Cv Service: 4.0
Cv Backwash: 3.8
Operating Pressures
Minimum / Maximum: 1°C – 55°C
Operating Temperatures
Minimum / Maximum: 20 psi – 125 psi
Meter
Accuracy: ±5%
Flow Rate Range: 0.25 – 30 gpm
Gallon Range: 0.01 – 999.99 m³
Dimensions & Weight
Distributor Pilot: 1.05" OD Pipe
Drain Line: 1" NPT
Brine Line: 3/8" Quick Connect
Mounting Base: 2 ½" - 8 NPSM
Height From Top Of Tank: 238197172 mm
Net/Gross Weight: 1.8 kg / 2.0 kg
Electrical Specifications
Supply Voltage: 110 - 120V / 220 - 240V
Supply Frequency: 50/60 Hz
Output Voltage: 15 VDC
Output Current: 1 A
Tank Applications
Water Softener: 6" – 16" Diameter
Water Filter: 6" – 16" Diameter
Cycles of Operation (Softener Downflow)
| Cycle | Time Range (minutes) | Default |
|---|---|---|
| 1. Backwash 1st (upflow) | 1 – 120 | 8 |
| 2. Regenerate Draw / Slow Rinse (downflow) | 1 – 180 | 60 |
| 3. Fast Rinse (downflow) | 1 – 180 | 60 |
| 4. Regenerant Refill (in service with treated water) | 1 – 120 | 8 |
| 5. Service (downflow) | — | — |
Note: Equipped with bypass